Applications * According to the standard IEC 60270, VDE 0434, ANSI as well as various IEEE standards * PD quality tests on high voltage equipment * PD diagnosis on developing insulating materials * Designed for on-site PD diagnosis tests as well as for manufacturing and research * PD fault location for power cables
User Benefits
* single or multi-channel (scaleable) * truly parallel and synchronous measurement of phi-Q-N pattern * stand-alone / handheld mode or remote controlled via LAN and PC * small compact design for stationary or on site use * features the well known LDIC Analysis and Diagnostics software * expandable for various PD / RIV applications up to tan δ / Power Factor
Specifications
PD detection:
* permanent detection of all PD events * digital, numeric real-time integration of PD events * integration in time and frequency range o time range: 100 ns .... 10 µs o frequency range: center frequency: 0 Hz .... 20 MHz o band width: 9 kHz, 30 kHz, 100 kHz, 300 kHz, 1 MHz, 3 MHz * charge evaluation full compatible to IEC 60270, VDE 0434, ANSI * single pulse detection: < 3 ns * max. double pulse resolution: <200ns (time range, superpositionerror < 1 %) * max. pulse frequency: 2 MHz * Input frequency range: o Voltage: DC to 10 kHz o PD signal: DC to 20 MHz * Input impedance: o Voltage: 1 MOhm o PD signal: 50 Ohm * Input voltage: o Voltage: 60 V rms (max) o PD signal: 10 V rms (max) * Dynamic range: o Voltage: 24 bit, 80 dB o PD signal: 14 bit, 100 dB * PD input protection: o input protection against over-voltage and short-circuit * PD input coupling: o DC, AC, Bias-Tee (optional) * Additional options: o Internal test generator, self-test of the signal way * Voltage supply: o 7 - 20 V DC, power: appr. 8 W, o external power supply with power pack (100 - 240 V, 50 - 60 Hz) * Control: o local, remote * Displays: o QVGA-Colour-Display, 4 Status-LED * Outputs: o 1 x LWL-Output, o 1 x Ethernet (10, 100, 1000 Mbit) - full-duplex * Inputs: o 2 x BNC (HF PD signal, NF voltage signal), o 1 x TTL signal for gating * Temperature range: o 0 °C to 55 °C (operation) o 0 °C to 70 °C (storage) * Humidity: o 5 % to 95 %, non-condense
Accessories
* Fault Location modul for PD Location in power cables (Reflectometer method) * UHF-modul (Attenuation: 0 dB / 26 dB / 38 dB, Band width: 110 MHz bis 1700 MHz) * LDC-5 - Calibrator for external calibration of the PD measuring circuit in pC of apparent charge up to 500 pC * LDJ-5 - Charge Injector for calibration of the PD measuring circuit with charge magnitudes up to 50000 pC * LDM-5 or LDM-5/U - Measuring impedance for signal and test voltage decoupling (bandwidth 20 MHz, maximum current 5 A, optional 50 A) * Docking station "Smart Dock" |